Concept Electronics

RVC Power Factor Controller


RVC Power Factor Controller
Price : 7,000.00 / Piece(s)
Get Best Price

MOQ : 1 Piece(s)

Business Type Manufacturer, Exporter
Mode Automatic
Dimension 144x144 mm
Operating Voltage 100-400
Click to view more

Preferred Buyer From

Location Anywhere in India

Product Details

Operating Current
1A-5A (RMS)
Capacitor Steps
4,6,8,12,14
Over Voltage Setting
Programable

Other Details

  • RVC has become synonymous with automatic capacitor bank controller in many markets worldwide thanks to its distinct design, ease of use, reliability and versatile functions.
  • Thanks to the user interface upgrade with graphical icons, it is possible to commission the RVC without a manual. A slimmer casing requires less space in the capacitor bank panel.
  • The RVC is an easy-to-install, easy to use, smarter power factor con- troller and an ideal companion of your automatic capacitor banks.


Powerful Features

  • Common range for a broad network voltages from 100V to 440V.
  • Measurement and display of key parameters like voltage, current, power factor, THDV and THDI.
  • Fully programmable switching sequence.
  • 1A or 5A current input.
  • Easy commissioning.
  • Complete auto set-up (starting current-C/k, type of switching sequence, phase shift, special connections).
  • Easy to use thanks to a user-friendly touchscreen interface and ease of access to parameters for manual setting.
  • Highly efficient switching strategy combining integral, direct and circular switching thereby allowing:
  • To control the cos in presence of rapidly varying loads,
  • To reduce the number of switching,
  • To avoid unnecessary intermediary switchings,
  • To increase the lifetime of the capacitors and contractors.
  • Suitable for hot environments due to maximum ambient temperature rating of 70°C.
  • Not affected by harmonics.
  • Overvoltage / undervoltage protection and protections against harmonic distortion (THDV).
  • Alarm : an alarm contact is opened when any of these conditions are reached:
  • The target cos Φ is not reached within 6 minutes after all outputs have been switched on,
  • The internal temperature of the RVC rises above 85°C,
  • Overvoltage / undervoltage limits are reached,
  • The power supply is out of range,
  • The THDV exceeds the limits.